FuriHal, Power, UnitTests: battery charging voltage limit API (#2063)
This commit is contained in:
@@ -7,6 +7,7 @@ static void power_settings_scene_battery_info_update_model(PowerSettingsApp* app
|
||||
.gauge_voltage = app->info.voltage_gauge,
|
||||
.gauge_current = app->info.current_gauge,
|
||||
.gauge_temperature = app->info.temperature_gauge,
|
||||
.charging_voltage = app->info.voltage_battery_charging,
|
||||
.charge = app->info.charge,
|
||||
.health = app->info.health,
|
||||
};
|
||||
|
@@ -68,6 +68,16 @@ static void draw_battery(Canvas* canvas, BatteryInfoModel* data, int x, int y) {
|
||||
drain_current > HIGH_DRAIN_CURRENT_THRESHOLD ? "mA!" : "mA");
|
||||
} else if(drain_current != 0) {
|
||||
snprintf(header, 20, "...");
|
||||
} else if(data->charging_voltage < 4.2) {
|
||||
// Non-default battery charging limit, mention it
|
||||
snprintf(emote, sizeof(emote), "Charged!");
|
||||
snprintf(header, sizeof(header), "Limited to");
|
||||
snprintf(
|
||||
value,
|
||||
sizeof(value),
|
||||
"%ld.%ldV",
|
||||
(uint32_t)(data->charging_voltage),
|
||||
(uint32_t)(data->charging_voltage * 10) % 10);
|
||||
} else {
|
||||
snprintf(header, sizeof(header), "Charged!");
|
||||
}
|
||||
|
@@ -9,6 +9,7 @@ typedef struct {
|
||||
float gauge_voltage;
|
||||
float gauge_current;
|
||||
float gauge_temperature;
|
||||
float charging_voltage;
|
||||
uint8_t charge;
|
||||
uint8_t health;
|
||||
} BatteryInfoModel;
|
||||
|
Reference in New Issue