FuriHal, Power, UnitTests: battery charging voltage limit API (#2063)
This commit is contained in:
@@ -341,6 +341,20 @@ bool furi_hal_power_is_otg_enabled() {
|
||||
return ret;
|
||||
}
|
||||
|
||||
float furi_hal_power_get_battery_charging_voltage() {
|
||||
furi_hal_i2c_acquire(&furi_hal_i2c_handle_power);
|
||||
float ret = (float)bq25896_get_vreg_voltage(&furi_hal_i2c_handle_power) / 1000.0f;
|
||||
furi_hal_i2c_release(&furi_hal_i2c_handle_power);
|
||||
return ret;
|
||||
}
|
||||
|
||||
void furi_hal_power_set_battery_charging_voltage(float voltage) {
|
||||
furi_hal_i2c_acquire(&furi_hal_i2c_handle_power);
|
||||
// Adding 0.0005 is necessary because 4.016f is 4.015999794000, which gets truncated
|
||||
bq25896_set_vreg_voltage(&furi_hal_i2c_handle_power, (uint16_t)(voltage * 1000.0f + 0.0005f));
|
||||
furi_hal_i2c_release(&furi_hal_i2c_handle_power);
|
||||
}
|
||||
|
||||
void furi_hal_power_check_otg_status() {
|
||||
furi_hal_i2c_acquire(&furi_hal_i2c_handle_power);
|
||||
if(bq25896_check_otg_fault(&furi_hal_i2c_handle_power))
|
||||
@@ -470,10 +484,10 @@ void furi_hal_power_info_get(PropertyValueCallback out, char sep, void* context)
|
||||
|
||||
if(sep == '.') {
|
||||
property_value_out(&property_context, NULL, 2, "format", "major", "2");
|
||||
property_value_out(&property_context, NULL, 2, "format", "minor", "0");
|
||||
property_value_out(&property_context, NULL, 2, "format", "minor", "1");
|
||||
} else {
|
||||
property_value_out(&property_context, NULL, 3, "power", "info", "major", "1");
|
||||
property_value_out(&property_context, NULL, 3, "power", "info", "minor", "0");
|
||||
property_value_out(&property_context, NULL, 3, "power", "info", "minor", "1");
|
||||
}
|
||||
|
||||
uint8_t charge = furi_hal_power_get_pct();
|
||||
@@ -481,7 +495,7 @@ void furi_hal_power_info_get(PropertyValueCallback out, char sep, void* context)
|
||||
|
||||
const char* charge_state;
|
||||
if(furi_hal_power_is_charging()) {
|
||||
if(charge < 100) {
|
||||
if((charge < 100) && (!furi_hal_power_is_charging_done())) {
|
||||
charge_state = "charging";
|
||||
} else {
|
||||
charge_state = "charged";
|
||||
@@ -491,6 +505,8 @@ void furi_hal_power_info_get(PropertyValueCallback out, char sep, void* context)
|
||||
}
|
||||
|
||||
property_value_out(&property_context, NULL, 2, "charge", "state", charge_state);
|
||||
uint16_t charge_voltage = (uint16_t)(furi_hal_power_get_battery_charging_voltage() * 1000.f);
|
||||
property_value_out(&property_context, "%u", 2, "charge", "voltage", charge_voltage);
|
||||
uint16_t voltage =
|
||||
(uint16_t)(furi_hal_power_get_battery_voltage(FuriHalPowerICFuelGauge) * 1000.f);
|
||||
property_value_out(&property_context, "%u", 2, "battery", "voltage", voltage);
|
||||
@@ -567,6 +583,13 @@ void furi_hal_power_debug_get(PropertyValueCallback out, void* context) {
|
||||
"charger",
|
||||
"vbat",
|
||||
bq25896_get_vbat_voltage(&furi_hal_i2c_handle_power));
|
||||
property_value_out(
|
||||
&property_context,
|
||||
"%d",
|
||||
2,
|
||||
"charger",
|
||||
"vreg",
|
||||
bq25896_get_vreg_voltage(&furi_hal_i2c_handle_power));
|
||||
property_value_out(
|
||||
&property_context,
|
||||
"%d",
|
||||
|
Reference in New Issue