FuriHal, Power, UnitTests: battery charging voltage limit API (#2063)
This commit is contained in:
@@ -132,6 +132,33 @@ bool bq25896_is_otg_enabled(FuriHalI2cBusHandle* handle) {
|
||||
return bq25896_regs.r03.OTG_CONFIG;
|
||||
}
|
||||
|
||||
uint16_t bq25896_get_vreg_voltage(FuriHalI2cBusHandle* handle) {
|
||||
furi_hal_i2c_read_reg_8(
|
||||
handle, BQ25896_ADDRESS, 0x06, (uint8_t*)&bq25896_regs.r06, BQ25896_I2C_TIMEOUT);
|
||||
return (uint16_t)bq25896_regs.r06.VREG * 16 + 3840;
|
||||
}
|
||||
|
||||
void bq25896_set_vreg_voltage(FuriHalI2cBusHandle* handle, uint16_t vreg_voltage) {
|
||||
if(vreg_voltage < 3840) {
|
||||
// Minimum value is 3840 mV
|
||||
bq25896_regs.r06.VREG = 0;
|
||||
} else {
|
||||
// Find the nearest voltage value (subtract offset, divide into sections)
|
||||
// Values are truncated downward as needed (e.g. 4200mV -> 4192 mV)
|
||||
bq25896_regs.r06.VREG = (uint8_t)((vreg_voltage - 3840) / 16);
|
||||
}
|
||||
|
||||
// Do not allow values above 23 (0x17, 4208mV)
|
||||
// Exceeding 4.2v will overcharge the battery!
|
||||
if(bq25896_regs.r06.VREG > 23) {
|
||||
bq25896_regs.r06.VREG = 23;
|
||||
}
|
||||
|
||||
// Apply changes
|
||||
furi_hal_i2c_write_reg_8(
|
||||
handle, BQ25896_ADDRESS, 0x06, *(uint8_t*)&bq25896_regs.r06, BQ25896_I2C_TIMEOUT);
|
||||
}
|
||||
|
||||
bool bq25896_check_otg_fault(FuriHalI2cBusHandle* handle) {
|
||||
furi_hal_i2c_read_reg_8(
|
||||
handle, BQ25896_ADDRESS, 0x0C, (uint8_t*)&bq25896_regs.r0C, BQ25896_I2C_TIMEOUT);
|
||||
|
Reference in New Issue