WS: Oregon2 - add support for temp sensor RTHN129 (#2088)
Co-authored-by: あく <alleteam@gmail.com>
This commit is contained in:
parent
e42dda7cfb
commit
741ad34b2c
@ -52,6 +52,11 @@ static const SubGhzBlockConst ws_oregon2_const = {
|
||||
#define ID_UV800 0xd874
|
||||
#define ID_THN129 0xcc43 // THN129 Temp only
|
||||
#define ID_RTHN129 0x0cd3 // RTHN129 Temp, clock sensors
|
||||
#define ID_RTHN129_1 0x9cd3
|
||||
#define ID_RTHN129_2 0xacd3
|
||||
#define ID_RTHN129_3 0xbcd3
|
||||
#define ID_RTHN129_4 0xccd3
|
||||
#define ID_RTHN129_5 0xdcd3
|
||||
#define ID_BTHGN129 0x5d53 // Baro, Temp, Hygro sensor
|
||||
#define ID_UVR128 0xec70
|
||||
#define ID_THGR328N 0xcc23 // Temp & Hygro sensor similar to THR228N with 5 channel instead of 3
|
||||
@ -137,11 +142,19 @@ static ManchesterEvent level_and_duration_to_event(bool level, uint32_t duration
|
||||
// From sensor id code return amount of bits in variable section
|
||||
// https://temofeev.ru/info/articles/o-dekodirovanii-protokola-pogodnykh-datchikov-oregon-scientific
|
||||
static uint8_t oregon2_sensor_id_var_bits(uint16_t sensor_id) {
|
||||
if(sensor_id == ID_THR228N) return 16;
|
||||
|
||||
if(sensor_id == ID_THGR122N) return 24;
|
||||
|
||||
switch(sensor_id) {
|
||||
case ID_THR228N:
|
||||
case ID_RTHN129_1:
|
||||
case ID_RTHN129_2:
|
||||
case ID_RTHN129_3:
|
||||
case ID_RTHN129_4:
|
||||
case ID_RTHN129_5:
|
||||
return 16;
|
||||
case ID_THGR122N:
|
||||
return 24;
|
||||
default:
|
||||
return 0;
|
||||
}
|
||||
}
|
||||
|
||||
static void ws_oregon2_decode_const_data(WSBlockGeneric* ws_block) {
|
||||
@ -171,16 +184,22 @@ static float ws_oregon2_decode_temp(uint32_t data) {
|
||||
}
|
||||
|
||||
static void ws_oregon2_decode_var_data(WSBlockGeneric* ws_b, uint16_t sensor_id, uint32_t data) {
|
||||
if(sensor_id == ID_THR228N) {
|
||||
switch(sensor_id) {
|
||||
case ID_THR228N:
|
||||
case ID_RTHN129_1:
|
||||
case ID_RTHN129_2:
|
||||
case ID_RTHN129_3:
|
||||
case ID_RTHN129_4:
|
||||
case ID_RTHN129_5:
|
||||
ws_b->temp = ws_oregon2_decode_temp(data);
|
||||
ws_b->humidity = WS_NO_HUMIDITY;
|
||||
return;
|
||||
}
|
||||
|
||||
if(sensor_id == ID_THGR122N) {
|
||||
case ID_THGR122N:
|
||||
ws_b->humidity = bcd_decode_short(data);
|
||||
ws_b->temp = ws_oregon2_decode_temp(data >> 8);
|
||||
return;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user