Weather Station: Fix display of temps lower than -9 (#2120)
Co-authored-by: あく <alleteam@gmail.com>
This commit is contained in:
		@@ -82,8 +82,14 @@ void ws_view_receiver_info_draw(Canvas* canvas, WSReceiverInfoModel* model) {
 | 
			
		||||
    if(model->generic->temp != WS_NO_TEMPERATURE) {
 | 
			
		||||
        canvas_draw_icon(canvas, 6, 43, &I_Therm_7x16);
 | 
			
		||||
        snprintf(buffer, sizeof(buffer), "%3.1f C", (double)model->generic->temp);
 | 
			
		||||
        canvas_draw_str_aligned(canvas, 47, 47, AlignRight, AlignTop, buffer);
 | 
			
		||||
        canvas_draw_circle(canvas, 38, 46, 1);
 | 
			
		||||
        uint8_t temp_x1 = 47;
 | 
			
		||||
        uint8_t temp_x2 = 38;
 | 
			
		||||
        if(model->generic->temp < -9.0) {
 | 
			
		||||
            temp_x1 = 49;
 | 
			
		||||
            temp_x2 = 40;
 | 
			
		||||
        }
 | 
			
		||||
        canvas_draw_str_aligned(canvas, temp_x1, 47, AlignRight, AlignTop, buffer);
 | 
			
		||||
        canvas_draw_circle(canvas, temp_x2, 46, 1);
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
    if(model->generic->humidity != WS_NO_HUMIDITY) {
 | 
			
		||||
 
 | 
			
		||||